XMM-Newton Science Analysis System
omdetect (omdetect-5.0.7) [xmmsas_20050815_1803-6.5.0]
Meta Index / Home Page
SourceListFile
- COLUMN NO NAME UNITS DESCRIPTION
- 1 SRCNUM none
- 2 XPOS pixels x-coordinate of
centroided source centre
- 3 YPOS pixels y-coordinate of
centroided source centre
- 4 POSERR pixels error in x and y
centroided position
- 5 RATE counts/sec Total measured source
counts (after background subtraction) within default source extraction aperture
(r=12 un-binned pixels), divided by exposure time.
- 6 RATE_ERR counts/sec
- 7 BACKGROUND_RATE counts/sec Total estimated
background counts (scaled by area ratio, from the background annulus)
within default source extraction aperture, divided by exposure time
- 8 SIGNIFICANCE none source counts /
sqrt(source + background counts) (i.e. signal-to-noise ratio)
- 9 CORR_RATE counts/sec Background subtracted
source count rate after extrapolating (if necessary) for the wings of the PSF
where they extend beyond the default extraction aperture, and correcting
for coincidence losses, time-degradation sensitivity and dead-time.
- 10 CORR_RATE_ERR counts/sec
- 11 CORR_BACKGROUND_RATE counts/sec BACKGROUND_RATE after
correcting for coincidence losses.
- 12 PSF1_CORR percentage Point-spread function
correction applied to extrapolate the RATE value from measurement aperture area
to the default extraction area of 12 unbinned pixels
- 13 COINCLOSS_CORR percentage Coincidence-loss correction
applied - (CORR_RATE - RATE) * 100.0 / RATE
- 14 NOPIXELS none Number of pixels contained by an
extended source (EFLAG=1). Point-sources (EFLAG=1) will have this value set to zero.
- 15 APERTURE unbinned pixels For point sources
(EFLAG=0), the aperture radius (unbinned pixels) used in the photometry. For
extended-sources (EFLAG=1) this value will be set to NULL.
- 16 FWHM_MAJ arcsecs The full-width-at-half-maximum
of the semi-major axis of the ellipse describing the shape of the source
(computed by moments)
- 17 FWHM_MIN arcsecs The full-width-at-half-maximum
of the semi-minor axis of the ellipse describing the shape of the source
(computed by moments)
- 18 PA degrees The postion-angle (measured
counterclockwise from the x-axis) of the semi-major axis of the ellipse
describing the shape of the source (computed from moments)
- 19 QFLAG none Source quality flag - Please see below
- 20 CFLAG none Source confusion flag - Please see below
- 21 EFLAG none (source extension flag) Either 0
point-source (none-extended) or 1 extended.
Quality flag settings
- Bit set, integer value, reason
- 0, 1, Source lies above one or more bad pixels
- 1, 2, Source may be affected by a read-out streak
- 2, 4, Source may be affected by a smoke-ring
- 3, 8, Source may be affected by a star diffraction spike
- 4, 16, Very bright source with a strong modula 8 pattern
- 5, 32, Source lies within central enhanced region
For example, a source with a bad pixel and lying on or close to a read-out streak
would have bits 0 and 1 set and thus have a quality flag value of 3.
Confusion flag settings
- Bit set, integer value, reason
- 0, 1, Point source has one or more sources within a radius of 6-12 unbinned pixels
- 1, 2, Point source has one or more sources within a radius of 3-6 unbinned pixels
- 2, 4, Source lies near to an edge of the image
- 3, 16, Source lies near to a bright source
- 4, 32, Point source lies partly or totally within an extended region
For example, a source lying near to an image edge and having a neighbour at a distance
of 10 unbinned pixels would have bits 2 and 1 set and would thus have a confusion flag value of
5.
XMM-Newton SOC/SSC -- 2005-08-16