badCalInfoStyle | error |
| The value of the calinfostyle parameter was not recognised. |
badNodeStr | error |
| The value of the mosccdnode parameter was not recognised. |
badOutUnit | error |
| The value of the outunit parameter was not recognised. |
badDataStyle | error |
| The value of the datastyle parameter was not recognised. |
emptyTableName | error |
| Parameter outtab was not given in the form dataSetName:tableName. |
notInFov | error |
| The calculated det XY position does not fall within the field of view. |
notInFov | warning |
|
corrective action: Task writes null values in the DETX and DETY columns. The calculated det XY position does not fall within the field of view. This may be overridden by setting checkfov=`no' |
notOnChip | warning |
| The calculated raw XY position does not fall on any ccd
corrective action: The task (i) calculates the RAWX/Y position relative to the nearest chip; (ii) either sets the FLAG column to 1 or writes F under `On chip?' in the output, depending on the value of datastyle. |