XMM-Newton SAS Home Page
XMM-Newton Science Analysis System


flspec (flspec-3.5.2) [xmmsas_20230412_1735-21.0.0]

Errors

This section documents warnings and errors generated by this task (if any). Note that warnings and errors can also be generated in the SAS infrastructure libraries, in which case they would not be documented here. Refer to the index of all errors and warnings available in the HTML version of the SAS documentation.

NotImgfatal 
 The input image does not contain an EPIC image
 
NotExpMapfatal 
 The input exposure map does not contain an EPIC exposure map
 
NonStandardInputfatal 
 The WCS keyword CDELT1 is missing in the input image
 
InvalidDatafatal 
 Input image does not have valid data
 
ErrStatfatal 
 It cannot calculate statistics for input Event List File using FTOOLS task fstatistic
 
ErrFarithfatal 
 The FTOOLS task farith cannot be run in the process explained by the associated message
 
ErrFcolparfatal 
 The FTOOLS task fcolpar cannot be run in the process explained by the associated message
 
ErrFimgstatfatal 
 The FTOOLS task fimgstat cannot be run in the process explained by the associated message
 
ErrFkeyparfatal 
 The FTOOLS task fkeypar cannot be run in the process explained by the associated message
 
ErrCpheadfatal 
 The FTOOLS task cphead cannot be run in the process explained by the associated message
 
ErrFparkeyfatal 
 The FTOOLS task fparkey cannot be run in the process explained by the associated message
 
ErrFpartabfatal 
 The FTOOLS task fpartab cannot be run in the process explained by the associated message
 
ErrFstructfatal 
 The FTOOLS task fstruct cannot be run in the process explained by the associated message
 
ErrFappendfatal 
 The FTOOLS task fappend cannot be run in the process explained by the associated message
 
ErrMathphafatal 
 Error raised while trying to run the FTOOLS task mathpha to subtract positive and negative spectra
 
ErrRegionfatal 
 The task region cannot be run on the input source list
 
ErrFlmaskfatal 
 Mask files cannot be created
 
ErrEvselectfatal 
 Problem raised while trying to run the task evselect in the process described by the associated message
 
ErrPseudofatal 
 Cannot create Pseudo Event List
 
ErrEmaskfatal 
 Error raised while trying to run the emask
 
BadParamValuefatal 
 The requested binsize in parameter binsize is smaller than the input image bin size, larger than the input image size or it results in a meaningless binned image with only one pixel
 
NoPixLeftfatal 
 The binned image does not have any pixels left after source subtraction
 
NullSpecPoswarning 
 Positive spectrum has null extraction area for offaxis value and fluctuations spectrum number given in the message
 
NullSpecNegwarning 
 Negative spectrum has null extraction area for offaxis value and fluctuations spectrum number given in the message
 
NullSpecwarning 
 Positive and Negative spectrum have null extraction area for offaxis value and fluctuations spectrum number given in the message
 
NullExpos1warning 
 Exposure value for positive and negative spectra cannot be properly updated by evselect in a given fluctuations spectrum (number specified)
corrective action: EXPOSURE is updated to 1.000 s
 
NullExposDswarning 
 Exposure value for positive and negative spectra cannot be properly updated by evselect in a given fluctuations spectrum (number specified) but Dataset has an EXPOSURE keyword
corrective action: EXPOSURE is updated to value in Dataset
 