XMM-Newton SAS Home Page
XMM-Newton Science Analysis System


odfingest (odfingest-3.33.1) [xmmsas_20230412_1735-21.0.0]

Data Quality Record

Finally there will be a data quality record for each instrument exposure and one for the spacecraft data. The following data quality information will be stored stored in the summary file: These items will be stored on a per exposure basis for each instrument and on a per observation basis for the spacecraft telemetry.

Data Quality Record

Line Offset Type Description Note
No.
1 0 A12, 58X 'DATA QUALITY' Note 1
2 0 A2, 1X Instrument Id. Note 2
2 3 A77 Comment Note 3
3 0 A13, 1X Exposure Id Note 4
3 5 A66 Comment Note 3
4 0 A4,1X Number of packets failing reception Note 5
4 5 A75 Comment Note 3
5 0 A4,1X Number of event reports Note 6
5 5 A75 Comment Note 3
6 0 A4,1X Number PMS errors Note 7
6 5 A75 Comment Note 3
7 0 A4,1X Number of telemetry drops Note 8
7 5 A75 Comment Note 3
8 0 A4,1X Total duration of telemetry drops Note 9
8 5 A75 Comment Note 3
9 0 A4,1X Number of out of limits Note 10
9 5 A75 Comment Note 3
10 0 A1,1X Unscheduled/ scheduled/ not applicable flag Note 11
10 3 A78 Comment Note 3
         

  1. Identifies the record as a Data Quality Record.
  2. The syntax is ii (Section [*]).
  3. All comments will have the syntax ' / text'.
  4. The syntax is ppppppoolliieee (Section [*]).
  5. Number of telemetry packets associated with the instrument/ spacecraft that failed reception during the period.
  6. Number of event reports produced by the instrument/ spacecraft during the period.
  7. Number of errors detected by the automatic telemetry processor for the instrument/ spacecraft during the period.
  8. Number of drops in the instrument/ spacecraft telemetry during the period.
  9. Total duration of the telemetry drops in the instrument/ spacecraft telemetry during the period.
  10. Number of out of limits detected in the instrument/ spacecraft telemetry during the period.
  11. Flag (S, U or X) indicating whether the exposure was scheduled (S) or unscheduled (U) and set to 'X' when it is not applicable (for the spacecraft data quality records).

XMM-Newton SOC -- 2023-04-16