| Parameter | Mand | Type | Default | Constraints |
| outputlistset | yes | filename | summarylist.fits | |
| Output summary
source list in FITS format | ||||
| htmloutput | yes | filename | summarylist.html | |
| Output summary source list in HTML format | ||||
| inputlistsets | yes | filename | inputlistset.fits | |
| EPIC
(emldetect) input source list(s). Specifying more than one list means
that these lists will be merged. | ||||
| crossidsets | no | filename | crossid.fits | |
|
Cross-identification source lists from earlier stages of the detection
pipeline. These files will be used to fill in the pointers to the source
identification numbers in these lists. | ||||
| usecrossidsets | no | Boolean | no | |
| Controls whether a cross correlation with X-ray source list from earlier detection stages should be performed. | ||||
| omlistset | no | filename | omlist.fits | |
| OM input source list. Setting omlistset=- means that no OM data set is available. | ||||
| useomlistset | no | Boolean | no | |
| Controls whether a cross correlation with an OM source list should be performed. | ||||
| systerr | no | float | 1.0 | [0.0 |
| Systematic error for EPIC source matching [arcsec] | ||||
| maxerr | no | float | 1.0 | [3.0 |
| Maximum allowed error (stat. + syst.) for EPIC source matching [sigmas]. | ||||
| omdist | no | float | 15.0 | [0.0 |
| Maximum distance EPIC–OM for correlation [arcsec] | ||||
| allepicmode | no | boolean | no | |
| Needs to be set, if one of the source
lists contains data from more than one EPIC camera, in order to calculate
combined count rates, fluxes, and hardness ratios. | ||||
| extentunit | no | string | image | |
| “image” or “sky”: choose the unit of
the extent-related output columns. | ||||
| Parameter | Mand | Type | Default | Constraints |
XMM-Newton SOC -- 2025-01-27