| Parameter | Mand | Type | Default | Constraints |
| imageset | yes | string | image | |
|
Input image FITS file (eg., P0123456789PNS003IMAGE_8000.FIT/FTZ).
| ||||
| withsrclist | no | boolean | true | |
|
Whether to use the source list in the observation.
| ||||
| srclisttab | yes | table | ||
|
Mandatory if withsrclist is true.
Source list (e.g., P0123456789EPX000OBSMLI0000.FIT/FTZ) in the observation.
| ||||
| withsrcrad | no | boolean | false | |
|
Extraction region radius for each source (SRC_RAD) from input Source List,
instead the tabulated LOOKUP.FITS table.
This parameter is read if withsrclist is true.
| ||||
| withcoords | no | boolean | false | |
|
Whether to give the coordinates in the command-line arguments.
This parameter is read if withsrclist is false.
| ||||
| coordtype | yes | string | eqpos | eqpos pos |
|
The coordinate system for which the source position, specified
by the parameter x and y, is defined.
If coordtype is set to eqpos, then x, y
correspond to RA and DEC respectively in decimal degrees.
If coordtype | ||||
| x | yes | real | ||
|
The X coordinate of the source position.
| ||||
| y | yes | real | ||
|
The Y coordinate of the source position.
| ||||
| r | yes | real | ||
|
Source extraction region radius in arcsec.
| ||||
| Parameter | Mand | Type | Default | Constraints |
XMM-Newton SOC -- 2021-01-26