Calibration Access and Data Handbook
Next: EPN_MODEPARAM
Up: EMOS_MODEPARAM
Previous: EMOS_MODEPARAM
Contents
One extension providing the list by instrument mode of important fixed
parameters such as readout dead time, frame times, live times, window sizes, etc ...
It allows to correct for mode dependent factors.
The CCF contains one table:
- MODEPARAM:
- table with characteristic parameters of the various observing modes, accessed by :
- Attributes:
-
- UNDER_X:
- Column under scan in pixels.
- OVER_X:
- Column over scan in pixels.
- UNDER_Y:
- Row under scan in pixels.
- OVER_Y:
- Row over scan in pixels.
- Columns:
-
- MODE_ID:
- numeric Mode identifier.
- INTEGRATION_T:
- Integration time (ms).
- SHIFT_T:
- Shift time (ms).
- FRAME_T:
- Frame time (ms).
- CYCLE_T:
- Cycle time (ms).
- TIME_RES:
- Time resolution (ms).
- DUTY_CYCLE:
- Duty cycle.
- SMEARED_FRAC:
- Smeared fraction.
- PTSRCE_PILEUP:
- Pile up count rate limit for point sources.
- LIMITING_FLUX:
- Maximum flux based on point source pile up considerations.
- WINDOWX0:
- X-coord. (PIXCOORD0) of lower left corner of readout window.
- WINDOWY0:
- Y-coord. (PIXCOORD0) of lower left corner of readout window.
- WINDOWDX:
- Width of readout window in X direction (pixels).
- WINDOWDY:
- Width of readout window in Y direction (pixels).