Errors

This section documents warnings and errors generated by this task (if any). Note that warnings and errors can also be generated in the SAS infrastructure libraries, in which case they would not be documented here. Refer to the index of all errors and warnings available in the HTML version of the SAS documentation.

NoMatchingCcfConstituentswarning 
 cifbuild did not find any CCF constituent matching the specified selection criteria.
corrective action: None.
 
PossibleInconsistentCalibrationwarning 
 The user specified analysisdate $<$ observationdate. The resulting Calibration Index File may contain a set of CCF constituents that are not consistent and lead to the wrong calibration being applied.
corrective action: None.
 
MissingAttributewarning 
 cifbuild expects to find a number of attributes in each CCF constituent. One or more of these attributes were not found.
corrective action: If a critical attribute is missing the constituent may be discarded at a later stage.
 
InvalidCcfConstituentwarning 
 cifbuild could not recognize a dataset as a valid CCF constituent.
corrective action: The dataset is ignroed.
 
TableNotFounderror 
 cifbuild was asked to open a calibration index file, but the required table was not found.
 
NoCcfPatherror 
 The environment variable SAS_CCFPATH is not set, and no CCF search path was given on the command line. See withccfpath.
 